http://www.rssboard.org/rss-specification720XTF Search Results (docsPerPage=100;f93-subject=Explorer 11)
http://ecuip-xtf.lib.uchicago.edu/xtf/search?docsPerPage%3D100;f93-subject%3DExplorer%2011
Results for your query: docsPerPage=100;f93-subject=Explorer 11Thu, 01 Jan 1970 12:00:00 GMTExplorer 11 Detector.
http://ecuip-xtf.lib.uchicago.edu/xtf/view?docId=grxr/George-Clark-Harvard/explorer-11_detector/explorer-11_detector.dc.xml
Draushaar and Clark’s detector for Explorer 11 was designed to detect gamma rays above 50 MeV. The image on the left shows the detector. It measured 20 inches high, 10 inches in diameter, and weighed about 30 pounds. The image on the right is a diagram of the detector, which consisted of a sandwich crystal scintillator and a Lucite Cherenkov counter, surrounded by a plastic anticoincidence scintillator.http://ecuip-xtf.lib.uchicago.edu/xtf/view?docId=grxr/George-Clark-Harvard/explorer-11_detector/explorer-11_detector.dc.xmlThu, 01 Jan 1970 12:00:00 GMTArtist’s Impression of the Explorer 11 in Orbit.
http://ecuip-xtf.lib.uchicago.edu/xtf/view?docId=grxr/NASA-Explorer-11-Flight/NASA-Explorer-11-Flight.dc.xml
Explorer 11, the first gamma-ray detection satellite flown, was launched on April 27, 1961. The satellite could not be actively pointed, so it was put into a tumble in order to get a "rough" scan of the entire celestial sphere..http://ecuip-xtf.lib.uchicago.edu/xtf/view?docId=grxr/NASA-Explorer-11-Flight/NASA-Explorer-11-Flight.dc.xmlThu, 01 Jan 1970 12:00:00 GMTExplorer 11 Detector.
http://ecuip-xtf.lib.uchicago.edu/xtf/view?docId=grxr/explorer-11_detector/explorer-11_detector.dc.xml
Draushaar and Clark’s detector for Explorer 11 was designed to detect gamma rays above 50 MeV. The image on the left shows the detector. It measured 20 inches high, 10 inches in diameter, and weighed about 30 pounds. The image on the right is a diagram of the detector, which consisted of a sandwich crystal scintillator and a Lucite Cherenkov counter, surrounded by a plastic anticoincidence scintillator.http://ecuip-xtf.lib.uchicago.edu/xtf/view?docId=grxr/explorer-11_detector/explorer-11_detector.dc.xmlThu, 01 Jan 1970 12:00:00 GMTExplorer 11 Detector.
http://ecuip-xtf.lib.uchicago.edu/xtf/view?docId=grxr/explorer-11_grbd/explorer-11_grbd.dc.xml
Kraushaar and Clark’s detector for Explorer 11 was designed to detect gamma rays above 50 MeV. The image on the left shows the detector. It measured 20 inches high, 10 inches in diameter, and weighed about 30 pounds. The image on the right is a diagram of the detector, which consisted of a sandwich crystal scintillator and a Lucite Cherenkov counter, surrounded by a plastic anticoincidence scintillator.http://ecuip-xtf.lib.uchicago.edu/xtf/view?docId=grxr/explorer-11_grbd/explorer-11_grbd.dc.xmlThu, 01 Jan 1970 12:00:00 GMT